Off-Board - AC DC Desktop, Wandadapter
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Filter anzeigen
Filter zurücksetzen
Filter anwenden
KategorieLeistung / Netzteile - Off-Board / Off-Board - AC DC Desktop, Wandadapter
Datensätze 12.523
Seite 175/418
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Ausgenutzte Region | Form | Eingabetyp | Spannung - Eingang | Spannung - Ausgang | Strom - Ausgang (max.) | Leistung (Watt) | Leerlaufstrom | Polarisation | Anwendungen | Effizienz | Betriebstemperatur | Ausgangsanschluss | Kabellänge | Eingangsanschluss | Größe / Dimension | Zulassungen |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
CUI |
AC-DC, 7.5 VDC, 4 A, SW, C8 DESK |
4.518 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 7.5V | 4A | 30W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 7.5 VDC, 4 A, SW, C8 DESK |
8.802 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 7.5V | 4A | 30W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 7.5 VDC, 4 A, SW, C8 DESK |
4.374 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 7.5V | 4A | 30W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 7.5 VDC, 4 A, SW, C8 DESK |
5.922 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 7.5V | 4A | 30W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 5 VDC, 5 A, SW, C8 DESK-T |
3.726 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 5V | 5A | 25W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 12 VDC, 3 A, SW, C8 DESK- |
5.220 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 12V | 3A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 18 VDC, 2 A, SW, C8 DESK- |
4.212 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 18V | 2A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 24 VDC, 1.5 A, SW, C8 DES |
7.974 |
|
SDM36-UD (36W) | North America | Desktop (Class II) | Cord | 90 ~ 264 VAC | 24V | 1.5A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 5 VDC/3 A, 9 VDC/3 A, 12 |
8.172 |
|
SWC27-N (27W) | North America | Wall Mount (Class II) | Fixed Blade | 90 ~ 264 VAC | 5V, 9V, 12V | 3A, 3A, 2.25A | 27W | 75mW (Max) | - | ITE (Commercial) | Level VI, CoC Tier 2 | 0°C ~ 40°C | USB C Receptacle | - | NEMA 1-15P | 1.74" L x 1.31" W x 2.07" H (44.2mm x 33.2mm x 52.5mm) | cULus, FCC, PSE |
|
![]() |
Inventus Power |
AC/DC DESKTOP ADAPTER 12V 30W |
5.904 |
|
MWA030 (30W) | International | Desktop (Class II) | Cord (Sold Separately) | 85 ~ 264 VAC | 12V | 2.5A | 30W | 300mW (Max) | Positive Center | Medical | Level V | 0°C ~ 60°C | - | 48" (1.22m) | IEC 320-C8 | 3.53" L x 1.92" W x 0.99" H (89.7mm x 48.8mm x 25.1mm) | CE, cTUVus |
|
![]() |
CUI |
AC-DC, 5 VDC, 5 A, SW, C8 DESK-T |
2.718 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 5V | 5A | 25W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 12 VDC, 3 A, SW, C8 DESK- |
4.590 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 12V | 3A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 18 VDC, 2 A, SW, C8 DESK- |
4.608 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 18V | 2A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 24 VDC, 1.5 A, SW, C8 DES |
7.902 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 24V | 1.5A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 5 VDC, 5 A, SW, C8 DESK-T |
8.946 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 5V | 5A | 25W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 5 VDC, 5 A, SW, C8 DESK-T |
6.354 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 5V | 5A | 25W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 5 VDC, 5 A, SW, C8 DESK-T |
8.226 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 5V | 5A | 25W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 9 VDC, 4 A, SW, C8 DESK-T |
4.716 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 9V | 4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 9 VDC, 4 A, SW, C8 DESK-T |
7.668 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 9V | 4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 9 VDC, 4 A, SW, C8 DESK-T |
7.902 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 9V | 4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 9 VDC, 4 A, SW, C8 DESK-T |
6.318 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 9V | 4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 12 VDC, 3 A, SW, C8 DESK- |
6.372 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 12V | 3A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 12 VDC, 3 A, SW, C8 DESK- |
8.604 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 12V | 3A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 12 VDC, 3 A, SW, C8 DESK- |
7.866 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 12V | 3A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 15 VDC, 2.4 A, SW, C8 DES |
4.230 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 15V | 2.4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 15 VDC, 2.4 A, SW, C8 DES |
2.142 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 15V | 2.4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 15 VDC, 2.4 A, SW, C8 DES |
2.916 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 15V | 2.4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 15 VDC, 2.4 A, SW, C8 DES |
4.698 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 15V | 2.4A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 18 VDC, 2 A, SW, C8 DESK- |
3.690 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 18V | 2A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug R/A, 2.1mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |
|
![]() |
CUI |
AC-DC, 18 VDC, 2 A, SW, C8 DESK- |
8.892 |
|
SDM36-UD (36W) | Europe | Desktop (Class II) | Cord | 90 ~ 264 VAC | 18V | 2A | 36W | 100mW (Max) | Positive Center | ITE (Commercial), Medical | Level VI | 0°C ~ 40°C | Barrel Plug, 2.5mm I.D. x 5.5mm O.D. x 9.5mm | 59" (1.50m) | IEC 320-C8 | 3.90" L x 1.97" W x 1.30" H (99.0mm x 50.0mm x 33.0mm) | CE, cURus, PSE, TUV |