KategorieLeistung / Schaltungsschutz / Gasentladungsrohrsperren (GDT)
Datensätze 3.195
Seite 94/107
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Spannung - DC Spark Over (Nom) | Impulsentladestrom (8 / 20µs) | Toleranz | Anzahl der Pole | Fail Short | Montagetyp | Paket / Fall |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Bourns |
GDT 200V 20% 10KA THROUGH HOLE |
2.448 |
|
Mini-TRIGARD™ 2036 | 200V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 200V 20% 10KA T/H FAIL SHORT |
8.982 |
|
Mini-TRIGARD™ 2036 | 200V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 230V 20% 10KA THROUGH HOLE |
5.454 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (T-Shape) |
|
|
Bourns |
GDT 230V 20% 10KA THROUGH HOLE |
4.932 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 230V 20% 10KA T/H FAIL SHORT |
6.606 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 230V 20% 10KA T/H FAIL SHORT |
8.496 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Radial - 3 Leads |
|
|
Bourns |
GDT 230V 20% 10KA T/H FAIL SHORT |
2.196 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, Radial Bend |
|
|
Bourns |
GDT 230V 20% 10KA THROUGH HOLE |
3.654 |
|
Mini-TRIGARD™ 2036 | 230V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (T-Shape) |
|
|
Bourns |
GDT 250V 20% 10KA THROUGH HOLE |
6.624 |
|
Mini-TRIGARD™ 2036 | 250V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 250V 20% 10KA THROUGH HOLE |
4.212 |
|
Mini-TRIGARD™ 2036 | 250V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 300V 20% 10KA THROUGH HOLE |
5.238 |
|
Mini-TRIGARD™ 2036 | 300V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 350V 20% 10KA THROUGH HOLE |
7.002 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 350V 20% 10KA T/H FAIL SHORT |
4.842 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 350V 20% 10KA THROUGH HOLE |
4.644 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 350V 20% 10KA T/H FAIL SHORT |
4.914 |
|
Mini-TRIGARD™ 2036 | 350V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 400V 20% 10KA THROUGH HOLE |
8.190 |
|
Mini-TRIGARD™ 2036 | 400V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 400V 20% 10KA T/H FAIL SHORT |
8.100 |
|
Mini-TRIGARD™ 2036 | 400V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole | Radial - 3 Leads |
|
|
Bourns |
GDT 420V 20% 10KA THROUGH HOLE |
7.722 |
|
Mini-TRIGARD™ 2036 | 420V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 420V 20% 10KA THROUGH HOLE |
3.060 |
|
Mini-TRIGARD™ 2036 | 420V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 470V 20% 10KA THROUGH HOLE |
8.622 |
|
Mini-TRIGARD™ 2036 | 470V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 470V 20% 10KA THROUGH HOLE |
5.760 |
|
Mini-TRIGARD™ 2036 | 470V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 600V 20% 10KA THROUGH HOLE |
8.892 |
|
Mini-TRIGARD™ 2036 | 600V | 10000A (10kA) | ±20% | 3 | No | Through Hole | Axial Cylinder, 3 Lead (Radial Bend) |
|
|
Bourns |
GDT 90V 20% 5KA THROUGH HOLE |
7.776 |
|
2037 | 90V | 5000A (5kA) | ±20% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns |
GDT 90V 20% 5KA THROUGH HOLE |
6.714 |
|
2037 | 90V | 5000A (5kA) | ±20% | 2 | No | Through Hole | Axial Cylinder, Radial Bend |
|
|
Bourns |
GDT 250V 15% 5KA THROUGH HOLE |
7.452 |
|
2037 | 250V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder, Radial Bend |
|
|
Bourns |
GDT 300V 15% 5KA THROUGH HOLE |
3.564 |
|
2037 | 300V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns |
GDT 300V 15% 5KA THROUGH HOLE |
3.186 |
|
2037 | 300V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder, Radial Bend |
|
|
Bourns |
GDT 350V 15% 5KA THROUGH HOLE |
8.262 |
|
2037 | 350V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns |
GDT 400V 15% 5KA THROUGH HOLE |
3.510 |
|
2037 | 400V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |
|
|
Bourns |
GDT 600V 15% 5KA THROUGH HOLE |
8.352 |
|
2037 | 600V | 5000A (5kA) | ±15% | 2 | No | Through Hole | Axial Cylinder |