Serie | Filtertyp | Konfiguration | Spannungs - DC | Spannung - Nennwechselstrom | Spannung - Nennwechselstrom (Phase zu Masse / Neutral) | Spannungs - Wechselstrom (Phase zu Phase) | Strom | Frequenz - Betrieb | Anwendungen | Zulassungen | Betriebstemperatur | Montagetyp | Kündigungsstil | Induktivität |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE; IR = 3 A; ILE |
8.370 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 10mH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
7.200 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 3A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 10mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 10A CHASS MNT |
3.400 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 9.5mH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
3.780 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 6A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 10mH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
4.320 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 8A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 6mH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
8.046 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 10A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 6mH |
|
![]() |
Altran Magnetics |
LINE FILTER 110/250VAC 6A CHAS |
4.446 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 16mH |
|
![]() |
Altran Magnetics |
LINE FILTER 110/250VAC 6A CHAS |
7.002 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 16mH |
|
![]() |
Altran Magnetics |
LINE FILTER 110/250VAC 6A CHAS |
2.736 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 6A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 16mH |
|
![]() |
Altran Magnetics |
LINE FILTER 20A CHASSIS MOUNT |
7.218 |
|
* | Three Phase (Wye) | Single Stage | - | - | - | - | 20A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 137µH |
|
![]() |
Altran Magnetics |
LINE FILTER 110/250VAC 1A CHAS |
2.232 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 1A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 22.4mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 30A CHASS MNT |
3.492 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 690µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 10A CHASS MNT |
7.272 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.2mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
6.714 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
8.352 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
5.022 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | Medical | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
3.060 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Quick Connect | 840µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 40A CHASS MNT |
4.284 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 590µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
6.246 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 700µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 15A CHASS MNT |
4.320 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 15A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | - |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
2.646 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 540µH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
8.946 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 12A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.2mH |
|
![]() |
Wurth Electronics |
SIZE SINGLE-STAGE ADVANCED; IR = |
4.266 |
|
* | Single Phase | Single Stage | 250V | 250V | - | - | 14A | 50/60Hz | General Purpose | cURus, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 2.2mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 12A CHASS MNT |
8.586 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 12A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.16mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 12A CHASS MNT |
5.670 |
|
* | Single Phase | Two Stage | - | 250V | - | - | 12A | DC ~ 400Hz | Safety | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1.16mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 30A CHASS MNT |
8.910 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 30A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 690µH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 10A CHASS MNT |
6.120 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 7.13mH |
|
![]() |
Schaffner EMC |
LINE FILTER 250VAC 500MA TH |
2.250 |
|
FN 410 | Single Phase | Two Stage | - | 250V | - | - | 500mA | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Through Hole | PC Pins | 24mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 10A CHASS MNT |
3.708 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | - | -10°C ~ 40°C | Chassis Mount | IEC 320-C14, Quick Connect | 7.13mH |
|
![]() |
Altran Magnetics |
LINE FILTER 250VAC 20A CHASS MNT |
2.268 |
|
* | Single Phase | Single Stage | - | 250V | - | - | 20A | DC ~ 400Hz | General Purpose | CE, cURus | -25°C ~ 100°C | Chassis Mount | Quick Connect | 600µH |