Datensätze 5.440
Seite 6/182
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Filtertyp | Konfiguration | Spannungs - DC | Spannung - Nennwechselstrom | Spannung - Nennwechselstrom (Phase zu Masse / Neutral) | Spannungs - Wechselstrom (Phase zu Phase) | Strom | Frequenz - Betrieb | Anwendungen | Zulassungen | Betriebstemperatur | Montagetyp | Kündigungsstil | Induktivität |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
7.560 |
|
K | Single Phase | Single Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (8-32) | 440µH |
|
|
Delta Electronics |
LINE FILTER 115/250VAC 20A CHASS |
14.016 |
|
DR | Single Phase | Two Stage | - | 115V, 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -25°C ~ 100°C | Chassis Mount | Quick Connect | 1mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 6A CHAS |
7.536 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 6A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 7.8mH |
|
|
TDK-EPCOS |
LINE FILTER 250VDC/VAC 10A CHASS |
8.136 |
|
B84113H | Single Phase | Two Stage | 250V | 250V | - | - | 10A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 3.9mH |
|
|
Delta Electronics |
LINE FILTER 75VAC 20A TH |
6.252 |
|
Delphi | DC | Three Stage | - | 75V | - | - | 20A | - | General Purpose | cUL, UL, VDE | -40°C ~ 110°C | Through Hole | PC Pins | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 6A CHASS MNT |
7.680 |
|
W | Single Phase | Two Stage | - | 250V | - | - | 6A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.9mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
14.184 |
|
V | Single Phase | Two Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.2mH |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 20A CHASS |
8.334 |
|
RSHN | Single Phase | Two Stage | 250V | 250V | - | - | 20A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 10A CHASS MNT |
7.680 |
|
MV | Single Phase | Two Stage | - | 250V | - | - | 10A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 12A CHASS |
7.080 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 12A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Quick Connect | 3.25mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 16A CHASS |
6.684 |
|
FN 2090 | Single Phase | Two Stage | - | 110V, 250V | - | - | 16A | DC ~ 400Hz | General Purpose | CE, CSA, ENEC, UR | -20°C ~ 100°C | Chassis Mount | Quick Connect | 4mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 15A CHASS MNT |
7.830 |
|
EMC | Single Phase | Two Stage | - | 250V | - | - | 15A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 3A CHASS MNT |
7.236 |
|
Q | Single Phase | Two Stage | - | 250V | - | - | 3A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Wire Leads | 32.18mH |
|
|
TDK-EPCOS |
LINE FILTER 250VDC/VAC 36A CHASS |
6.390 |
|
B84111F | Single Phase | Single Stage | 250V | 250V | - | - | 36A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M5) | 400µH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
13.032 |
|
EMC | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 12A CHASS MNT |
7.236 |
|
EP | Single Phase | Two Stage | - | 250V | - | - | 12A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 7.88mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
15.792 |
|
EP | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
8.730 |
|
V | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 1.8mH |
|
|
Schaffner EMC |
LINE FILTER 110/250VAC 36A CHASS |
6.276 |
|
FN 2070 | Single Phase | Two Stage | - | 110V, 250V | - | - | 36A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Threaded Post (M4) | 1.23mH |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 40A CHASS MNT |
6.132 |
|
SK | Single Phase | Single Stage | - | 250V | - | - | 40A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (10-32) | 2.3mH |
|
|
TDK-Lambda |
LINE FILTER 250VDC/VAC 40A CHASS |
237 |
|
RSEN | Single Phase | Single Stage | 250V | 250V | - | - | 40A | - | General Purpose | CSA, EN, UL | -25°C ~ 85°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 250VAC 45A CHASS MNT |
5.598 |
|
FN 2410 | Single Phase | Single Stage | - | 250V | - | - | 45A | DC ~ 400Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 20A CHASSIS MOUNT |
6.084 |
|
FN 3025 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 20A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Schaffner EMC |
LINE FILTER 480VAC 10A CHASS MNT |
6.570 |
|
FN 3270 | Three Phase (Delta) | Single Stage | - | 480V | 300V | 520V | 10A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 250VAC 20A CHASS MNT |
6.966 |
|
Q | Single Phase | Two Stage | - | 250V | - | - | 20A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 40°C | Chassis Mount | Quick Connect | 6mH |
|
|
Schaffner EMC |
LINE FILTER 20A DIN RAIL |
4.410 |
|
FN 3026 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 20A | 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | DIN Rail | Terminal Block | - |
|
|
TE Connectivity Corcom Filters |
LINE FILTER 80VDC 15A CHASS MNT |
5.238 |
|
DC | DC | Single Stage | 80V | - | - | - | 15A | - | General Purpose | CSA, TUV, UR | -10°C ~ 55°C | Chassis Mount | Threaded Post (8-32) | 451µH |
|
|
Schaffner EMC |
LINE FILTER 30A CHASSIS MOUNT |
7.434 |
|
FN 3025 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 30A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
|
Curtis Industries |
LINE FILTER 80VDC 100A CHASS MNT |
7.308 |
|
FD | DC | Single Stage | 80V | - | - | - | 100A | - | General Purpose | cUR, TUV, UR | - | Chassis Mount | Threaded Post (8-32) | - |
|
|
Schaffner EMC |
LINE FILTER 7A CHASSIS MOUNT |
6.390 |
|
FN 3258 | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 7A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |