KategoriePassive Komponenten / Filter / Power Line Filter Module
Datensätze 5.440
Seite 21/182
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Filtertyp | Konfiguration | Spannungs - DC | Spannung - Nennwechselstrom | Spannung - Nennwechselstrom (Phase zu Masse / Neutral) | Spannungs - Wechselstrom (Phase zu Phase) | Strom | Frequenz - Betrieb | Anwendungen | Zulassungen | Betriebstemperatur | Montagetyp | Kündigungsstil | Induktivität |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Schaffner EMC |
LINE FILTER 42A CHASSIS MOUNT |
5.076 |
|
FN 3258 | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 42A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 25A CHASSIS MOUNT |
6.840 |
|
FCD | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 25A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 30A CHASSIS MOUNT |
8.478 |
|
FN 3268 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 30A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 36A CHASSIS MOUNT |
6.108 |
|
FN 356 | Three Phase (Wye) | Single Stage | - | - | 250V | 440V | 36A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
TDK-EPCOS |
LINE FILTER 520/300VAC 120A CHAS |
5.436 |
|
B84143A | Three Phase (Delta) | Single Stage | - | 520V, 300V | - | - | 120A | 50/60Hz | General Purpose | cUR, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 36A CHASSIS MOUNT |
6.354 |
|
FN 356 | Three Phase (Wye) | Single Stage | - | - | 250V | 440V | 36A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 1KVDC 250A CHASS |
3.852 |
|
FN 2211 | DC | Single Stage | 1000V (1kV) | - | - | - | 250A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
Delta Electronics |
LINE FILTER 480VAC 100A CHASS |
5.796 |
|
TDV | Three Phase (Delta) | Single Stage | - | 480V | - | - | 100A | 50/60Hz | General Purpose | cURus, ENEC, SEMKO | -25°C ~ 100°C | Chassis Mount | Terminal Block | 300µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 20A CHASSIS MOUNT |
7.686 |
|
A | Three Phase (Wye) | Two Stage | - | - | 250V | 440V | 20A | 50/60Hz | General Purpose | CSA, UL, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 7mH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 30A CHASSIS MOUNT |
4.032 |
|
A | Three Phase (Wye) | Two Stage | - | - | 250V | 440V | 30A | 50/60Hz | General Purpose | CSA, UL, VDE | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 3.32mH |
|
![]() |
Schaffner EMC |
LINE FILTER 35A CHASSIS MOUNT |
8.676 |
|
FN 3100 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 35A | DC ~ 60Hz | Regenerative Motor Drive | CSA, SEMKO, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 50A CHASSIS MOUNT |
6.210 |
|
FCD | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 50A | 50/60Hz | Regenerative Motor Drive | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 60A CHASSIS MOUNT |
7.398 |
|
A | Three Phase (Wye) | Two Stage | - | - | 250V | 440V | 60A | 50/60Hz | General Purpose | CSA, UL | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 740µH |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 63A CHASSIS MOUNT |
5.670 |
|
AYC | Three Phase (Wye) | Single Stage | - | - | 277V | 480V | 63A | 50/60Hz | General Purpose | UR | -10°C ~ 40°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 55A CHASSIS MOUNT |
7.326 |
|
FN 3258 | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 55A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 1.2KVDC 250A CHASS |
5.652 |
|
FN 2200 | DC | Single Stage | 1200V (1.2kV) | - | - | - | 250A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 75A CHASSIS MOUNT |
7.758 |
|
BCFXR | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 75A | 50/60Hz | General Purpose | CSA, UR, VDE | -10°C ~ 50°C | Chassis Mount | Terminal Block | 1.06mH |
|
![]() |
Schaffner EMC |
LINE FILTER 1KVDC 400A CHASS |
6.138 |
|
FN 2211 | DC | Single Stage | 1000V (1kV) | - | - | - | 400A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 180A CHASSIS MOUNT |
7.470 |
|
BCF | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 180A | 50/60Hz | Inverters, Power Drive Systems | UR, VDE | -10°C ~ 50°C | Chassis Mount | Threaded Post (M10) | - |
|
![]() |
Schaffner EMC |
LINE FILTER 75A CHASSIS MOUNT |
6.444 |
|
FN 258 | Three Phase (Delta) | Two Stage | - | - | 277V | 480V | 75A | DC ~ 60Hz | Inverters, Power Drive Systems | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 75A CHASSIS MOUNT |
4.788 |
|
FN 3258 | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 75A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 80A CHASSIS MOUNT |
6.588 |
|
FN 256 | Three Phase (Wye) | Single Stage | - | - | 277V | 480V | 80A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
Schaffner EMC |
LINE FILTER 520/300VAC 250A CHAS |
7.776 |
|
FN 3311 | Three Phase (Delta) | Single Stage | - | 520V, 300V | 300V | 520V | 250A | 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
Schaffner EMC |
LINE FILTER 1.2KVDC 400A CHASS |
7.704 |
|
FN 2200 | DC | Single Stage | 1200V (1.2kV) | - | - | - | 400A | - | Photovoltaic Inverter | cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
Schaffner EMC |
LINE FILTER 1KVDC 600A CHASS |
4.248 |
|
FN 2211 | DC | Single Stage | 1000V (1kV) | - | - | - | 600A | DC | Inverters, Power Drive Systems | CE, cURus | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
Schaffner EMC |
LINE FILTER 130A CHASSIS MOUNT |
3.888 |
|
FN 3258 | Three Phase (Delta) | Single Stage | - | - | 277V | 480V | 130A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |
|
![]() |
TE Connectivity Corcom Filters |
LINE FILTER 60A CHASSIS MOUNT |
5.166 |
|
A | Three Phase (Wye) | Two Stage | - | - | 250V | 440V | 60A | 50/60Hz | General Purpose | CSA, UL | -10°C ~ 40°C | Chassis Mount | Threaded Post (1/4-20) | 1.48mH |
|
![]() |
Schaffner EMC |
LINE FILTER 520VAC 400A CHASS |
7.290 |
|
FN 3310 | Three Phase (Delta) | Single Stage | - | 520V | - | 520V | 400A | DC ~ 60Hz | General Purpose | CE, cURus, ENEC | -40°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
TDK-EPCOS |
LINE FILTER 520/300VAC 250A CHAS |
8.568 |
|
B84143B | Three Phase (Delta) | Two Stage | - | 520V, 300V | - | - | 250A | 50/60Hz | General Purpose | cUR, UR | -25°C ~ 100°C | Chassis Mount | Terminal Post | - |
|
![]() |
Schaffner EMC |
LINE FILTER 130A CHASSIS MOUNT |
5.922 |
|
FN 3268 | Three Phase (Delta) | Single Stage | - | - | 300V | 520V | 130A | DC ~ 60Hz | General Purpose | CSA, ENEC, UR | -25°C ~ 100°C | Chassis Mount | Terminal Block | - |