Tantalpolymerkondensatoren
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Filter anzeigen
Filter zurücksetzen
Filter anwenden
KategoriePassive Komponenten / Kondensatoren / Tantalpolymerkondensatoren
Datensätze 7.363
Seite 199/246
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Kapazität | Toleranz | Spannung - Nennspannung | Typ | ESR (Equivalent Series Resistance) | Betriebstemperatur | Lifetime @ Temp. | Montagetyp | Paket / Fall | Größe / Dimension | Sitzhöhe (max.) | Leitungsabstand | Herstellergrößencode | Bewertungen | Funktionen |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
KEMET |
CAP TANT POLY 25UF 100V AXIAL |
8.928 |
|
T550 | 25µF | ±10% | 100V | Hermetically Sealed | 190 mOhm | -55°C ~ 105°C | 2000 Hrs @ 105°C | Through Hole | Axial | 0.279" Dia x 0.650" L (7.09mm x 16.51mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 75UF 75V AXIAL |
2.970 |
|
T550 | 75µF | ±10% | 75V | Hermetically Sealed | 110 mOhm | -55°C ~ 105°C | 2000 Hrs @ 105°C | Through Hole | Axial | 0.279" Dia x 0.650" L (7.09mm x 16.51mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 75UF 75V AXIAL |
6.012 |
|
T550 | 75µF | ±10% | 75V | Hermetically Sealed | 110 mOhm | -55°C ~ 105°C | 2000 Hrs @ 105°C | Through Hole | Axial | 0.279" Dia x 0.650" L (7.09mm x 16.51mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 140UF 6.3V AXIAL |
3.330 |
|
T551 | 140µF | ±10% | 6.3V | Hermetically Sealed | 120 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 820UF 6.3V AXIAL |
4.968 |
|
T551 | 820µF | ±10% | 6.3V | Hermetically Sealed | 90 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 220UF 8V AXIAL |
3.168 |
|
T551 | 220µF | ±10% | 8V | Hermetically Sealed | 120 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 680UF 8V AXIAL |
3.690 |
|
T551 | 680µF | ±10% | 8V | Hermetically Sealed | 90 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 100UF 10V AXIAL |
7.236 |
|
T551 | 100µF | ±10% | 10V | Hermetically Sealed | 140 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 180UF 10V AXIAL |
4.770 |
|
T551 | 180µF | ±10% | 10V | Hermetically Sealed | 110 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 560UF 10V AXIAL |
8.496 |
|
T551 | 560µF | ±10% | 10V | Hermetically Sealed | 90 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 70UF 15V AXIAL |
4.356 |
|
T551 | 70µF | ±10% | 15V | Hermetically Sealed | 140 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 120UF 15V AXIAL |
2.358 |
|
T551 | 120µF | ±10% | 15V | Hermetically Sealed | 110 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 390UF 15V AXIAL |
6.750 |
|
T551 | 390µF | ±10% | 15V | Hermetically Sealed | 90 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 50UF 25V AXIAL |
2.988 |
|
T551 | 50µF | ±10% | 25V | Hermetically Sealed | 170 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 100UF 25V AXIAL |
3.078 |
|
T551 | 100µF | ±10% | 25V | Hermetically Sealed | 190 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 40UF 30V AXIAL |
3.276 |
|
T551 | 40µF | ±10% | 30V | Hermetically Sealed | 170 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 68UF 30V AXIAL |
6.984 |
|
T551 | 68µF | ±10% | 30V | Hermetically Sealed | 140 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 100UF 40V AXIAL |
6.120 |
|
T551 | 100µF | ±10% | 40V | Hermetically Sealed | 150 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 120UF 40V AXIAL |
6.318 |
|
T551 | 120µF | ±10% | 40V | Hermetically Sealed | 120 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 25UF 50V AXIAL |
4.176 |
|
T551 | 25µF | ±10% | 50V | Hermetically Sealed | 170 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 47UF 50V AXIAL |
3.870 |
|
T551 | 47µF | ±10% | 50V | Hermetically Sealed | 150 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 100UF 50V AXIAL |
2.322 |
|
T551 | 100µF | ±10% | 50V | Hermetically Sealed | 130 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 120UF 50V AXIAL |
3.906 |
|
T551 | 120µF | ±10% | 50V | Hermetically Sealed | 90 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 20UF 60V AXIAL |
8.964 |
|
T551 | 20µF | ±10% | 60V | Hermetically Sealed | 200 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 39UF 60V AXIAL |
4.248 |
|
T551 | 39µF | ±10% | 60V | Hermetically Sealed | 160 mOhm | -55°C ~ 125°C | 2000 Hrs @ 85°C | Through Hole | Axial, Can | 0.312" Dia x 0.641" L (7.92mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 100UF 60V AXIAL |
5.598 |
|
T550 | 100µF | ±20% | 60V | Hermetically Sealed | 100 mOhm | -55°C ~ 105°C | 2000 Hrs @ 85°C | Through Hole | Axial | 0.281" Dia x 0.641" L (7.14mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 140UF 6V AXIAL |
3.978 |
|
T550 | 140µF | ±10% | 6V | Hermetically Sealed | - | -55°C ~ 105°C | 2000 Hrs @ 85°C | Through Hole | Axial | 0.281" Dia x 0.641" L (7.14mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 820UF 6V AXIAL |
6.372 |
|
T550 | 820µF | ±10% | 6V | Hermetically Sealed | - | -55°C ~ 105°C | 2000 Hrs @ 85°C | Through Hole | Axial | 0.281" Dia x 0.641" L (7.14mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 220UF 8V AXIAL |
6.678 |
|
T550 | 220µF | ±10% | 8V | Hermetically Sealed | - | -55°C ~ 105°C | 2000 Hrs @ 85°C | Through Hole | Axial | 0.281" Dia x 0.641" L (7.14mm x 16.28mm) | - | - | B | - | General Purpose |
|
|
KEMET |
CAP TANT POLY 680UF 8V AXIAL |
5.580 |
|
T550 | 680µF | ±10% | 8V | Hermetically Sealed | - | -55°C ~ 105°C | 2000 Hrs @ 85°C | Through Hole | Axial | 0.281" Dia x 0.641" L (7.14mm x 16.28mm) | - | - | B | - | General Purpose |