Leistungsschalter
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Loading...
Filter anzeigen
Filter zurücksetzen
Filter anwenden
KategorieLeistung / Schaltungsschutz / Leistungsschalter
Datensätze 42.170
Seite 726/1406
Bild |
Teilenummer |
Hersteller |
Beschreibung |
Auf Lager |
Menge |
Serie | Unterbrechertyp | Nennstrom (Ampere) | Nennspannung - AC | Nennspannung - DC | Anzahl der Pole | Aktuatortyp | Beleuchtung | Beleuchtungsspannung (nominal) | Montagetyp | Zulassungen |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 8A |
5.148 |
|
IEG | Magnetic (Hydraulic Delay) | 8A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 50A |
2.214 |
|
IEG | Magnetic (Hydraulic Delay) | 50A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 30A |
3.456 |
|
IEG | Magnetic (Hydraulic Delay) | 30A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 45A |
3.384 |
|
IEG | Magnetic (Hydraulic Delay) | 45A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 25A |
7.848 |
|
IEG | Magnetic (Hydraulic Delay) | 25A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 2A |
4.410 |
|
IEG | Magnetic (Hydraulic Delay) | 2A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 50A |
6.498 |
|
IUG | Magnetic (Hydraulic Delay) | 50A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 5A |
3.204 |
|
IUG | Magnetic (Hydraulic Delay) | 5A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER 8A |
4.284 |
|
IUG | Magnetic (Hydraulic Delay) | 8A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 10A LEVER |
5.706 |
|
IEG | Magnetic (Hydraulic Delay) | 10A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 15A LEVER |
4.194 |
|
IEG | Magnetic (Hydraulic Delay) | 15A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 20A LEVER |
2.898 |
|
IEG | Magnetic (Hydraulic Delay) | 20A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 20A LEVER |
3.078 |
|
IEG | Magnetic (Hydraulic Delay) | 20A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR 20A LEVER |
7.704 |
|
IUG | Magnetic (Hydraulic Delay) | 20A | - | - | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
6.696 |
|
IEG | Magnetic (Hydraulic Delay) | 5A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
3.744 |
|
IEG | Magnetic (Hydraulic Delay) | 15A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
3.078 |
|
IEG | Magnetic (Hydraulic Delay) | 15A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
8.856 |
|
IEG | Magnetic (Hydraulic Delay) | 10A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
3.132 |
|
IEG | Magnetic (Hydraulic Delay) | 40A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
3.186 |
|
IEG | Magnetic (Hydraulic Delay) | 30A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR |
4.410 |
|
IUG | Magnetic (Hydraulic Delay) | 35A | 250V | 80V | 2 | Lever | None | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR LEVER |
5.760 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | - | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR 20A 250VAC 80VDC |
7.380 |
|
IEG | Magnetic (Hydraulic Delay) | 20A | 250V | 80V | 2 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
6.714 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
5.418 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIR BRKR MAG-HYDR ROCKER |
7.146 |
|
LEL | Magnetic (Hydraulic Delay) | - | - | - | 1 | Rocker | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BRKR MAG-HYDR LEVER 10A |
3.420 |
|
CEG | Magnetic (Hydraulic Delay) | 10A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
Sensata-Airpax |
CIRCUIT BRKR MAG-HYDR LEVER 30A |
6.012 |
|
CEG | Magnetic (Hydraulic Delay) | 30A | - | - | 1 | Lever | - | - | Panel Mount | - |
|
![]() |
E-T-A |
CIR BRKR 10MA 120VAC 60VDC |
6.894 |
|
808 | Magnetic (Hydraulic Delay) | 10mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |
|
![]() |
E-T-A |
CIR BRKR 30MA 120VAC 60VDC |
5.256 |
|
808 | Magnetic (Hydraulic Delay) | 30mA | 120V | 60V | 1 | Push-Pull Plunger | - | - | Through Hole | CSA C22.2 No 235, UL1077 |